The rsd_lib.resources.v2_1.chassis.power_zone Module¶
-
class
rsd_lib.resources.v2_1.chassis.power_zone.PowerSupplyCollectionField(*args, **kwargs)¶ Bases:
sushy.resources.base.ListField-
firmware_revision= <sushy.resources.base.Field object>¶ The firmware version for this Power Supply
-
last_power_output_watts= <sushy.resources.base.Field object>¶ The average power output of this Power Supply
-
manufacturer= <sushy.resources.base.Field object>¶ The manufacturer of this Power Supply
-
model_number= <sushy.resources.base.Field object>¶ The model number for this Power Supply
-
name= <sushy.resources.base.Field object>¶ The Power Supply name
-
part_number= <sushy.resources.base.Field object>¶ The part number for this Power Supply
-
power_capacity_watts= <sushy.resources.base.Field object>¶ The maximum capacity of this Power Supply
-
rack_location= <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶ The PowerZone physical location
-
serial_number= <sushy.resources.base.Field object>¶ The serial number for this Power Supply
-
status= <rsd_lib.base.StatusField object>¶ The Power supply status
-
-
class
rsd_lib.resources.v2_1.chassis.power_zone.PowerZone(connector, path='', redfish_version=None, registries=None, reader=None, json_doc=None, root=None)¶ Bases:
rsd_lib.base.ResourceBase-
max_psus_supported= <sushy.resources.base.Field object>¶ The maximum number of Power Supply Units supported by PowerZone
-
number_of_psus_present= <sushy.resources.base.Field object>¶ Indicates the number of existing Power Supply Units in PowerZone
-
power_capacity_watts= <sushy.resources.base.Field object>¶ The maximum power capacity supported by PowerZone
-
power_consumed_watts= <sushy.resources.base.Field object>¶ The total power consumption of PowerZone, sum of trays’ power consumption
-
power_output_watts= <sushy.resources.base.Field object>¶ The total power production of PowerZone, sum of PSUs’ output
-
power_supplies= <rsd_lib.resources.v2_1.chassis.power_zone.PowerSupplyCollectionField object>¶ Details of the power supplies associated with this system or device
-
presence= <sushy.resources.base.Field object>¶ Indicates the aggregated Power Supply Unit presence information Aggregated Power Supply Unit presence format: Length of string indicate total slot of Power Supply Units in PowerZone.
For each byte the string: “1” means present “0” means not present
-
rack_location= <rsd_lib.resources.v2_1.common.rack_location.RackLocationField object>¶ The PowerZone physical location
-
status= <rsd_lib.base.StatusField object>¶ The PowerZone status
-
-
class
rsd_lib.resources.v2_1.chassis.power_zone.PowerZoneCollection(connector, path, redfish_version=None, registries=None, root=None)¶